Hydraulic closing is a method, not a complete specification.

Hydraulic closing and pressure keeping

The catalogue describes an electrical-contact pressure meter used in the pressure-keeping arrangement. Hydraulic refers to the closing method; it does not uniquely identify every filtration or automation feature.

Manual discharge in the described range

The catalogue states that cake discharge is manual. The selected photographs identify the hydraulic family but do not establish the plate/frame or chamber subtype, exact model, or any additional automation.

Understand this equipment family.

01

Pressure-keeping arrangement

The electrical-contact pressure-meter arrangement is described in the catalogue. Confirm its actual controls, pressure definitions and operation for the selected equipment.

02

Frame and surface treatment

Q235 carbon steel, sandblasting/descaling and painting are described. Confirm the frame material, coating and corrosion requirements; this is not a blanket corrosion-resistance guarantee.

03

Plate material selection

The catalogue describes plates without recycled material or other filler. Verify the actual plate material and its chemical/temperature limits in the model specification; the description does not establish universal acid, alkali or food-contact suitability.

04

Filter cloth choices

Different cloths are described for different materials. Select media against the feed and separation requirement rather than assuming a single filtration accuracy for the family.

Review the source parameters.

17 source rows

Scroll sideways to view all table columns. Confirm the exact model and configuration before using these reference figures.

Supplied source rows — not a binding specification for the photographed machine
Source row ID¹Area
(m²)
Plate size
(mm)
Cake thickness
(mm)
Chamber volume
(L)
Plate countFrame countMotor
(kW)
Source weight
(kg)
L × W × H
(mm)
4/5004500 × 50030609102.28602080×800×900
6/5006500 × 500309114152.29102380×800×900
8/5008500 × 5003012119202.29602680×800×900
10/50010500 × 5003015124252.210102980×800×900
12/50012500 × 5003018229302.210603280×800×900
15/50015500 × 5003022536372.211303700×800×900
16/50016500 × 5003024339402.211603880×800×900
15/70015700 × 7003022618192.217252840×1000×1060
20/70020700 × 7003029724252.219933200×1000×1060
30/70030700 × 7003045237382.223603980×1000×1060
40/70040700 × 7003059549502.227884800×1000×1060
30/89030890 × 8903552423242.225803740×1385×1250
40/89040890 × 8903567730312.229254220×1385×1250
50/89050890 × 8903585238392.233184880×1385×1250
60/89060890 × 89035102746472.237125440×1385×1250
70/89070890 × 89035120154552.241066008×1385×1250
80/89080890 × 89035137662632.245616560×1385×1250

¹ Reference row labels. Area and plate dimension identify a source row. Unclear model-code suffixes have not been reconstructed.

Plate and frame columns remain distinct. The sheet contains both plate count and frame count. This does not by itself establish which count or subtype matches a photographed machine.

Source model groups include /450 and /630, while the plate column prints 500 × 500 and 700 × 700 mm; the third group prints 890 × 890 mm. Read the actual plate-size column and confirm the exact code.

The sheet prints ≤0.5 MPa in its pressure column. Model-specific filtration/closing limits remain unconfirmed, so that figure is not adopted as a rating for the photographed press.

Source: the supplied Hydraulic Filter Press parameter sheet, page1. Overall dimensions are source values; foundation figures are not used as installation instructions. Pressure ratings require model-specific verification.

Resolve the model-specific limits.

Confirm subtype before final selection.

Specify whether the required configuration is chamber or plate-and-frame, together with the intended feed, cloth, closing system and cake handling. Confirm actual model and pressure definitions.

Scope of source evidence

The catalogue’s application paragraph names a program-controlled automatic press, despite the document being titled Hydraulic Filter Press. That copied paragraph is not used here as verified hydraulic application evidence. No universal capacity, precision, chemical compatibility or lifetime claim is made.

Structure, installation and care.

Match the closing system and pack.

A selected-model drawing is needed to identify the hydraulic closing arrangement, plate/frame or chamber pack, feed and filtrate interfaces and manual discharge access.

Awaiting selected-model documents

General arrangement, foundation/connection schedule, hydraulic and electrical interfaces, safe discharge procedure, cloth/plate care and maintenance manual. The unreviewed source video is not used as an operating guide.

Start with the actual material.

Discuss the actual stream.

The supplied product template lists pressure solid–liquid separation across process and wastewater contexts. For this hydraulic family, the catalogue’s copied application paragraph is insufficient to confirm a particular industry or process.

Provide the material, feed chemistry and temperature, solids loading, intended separation and cake-handling arrangement so that subtype and media can be checked.

Hydraulic-family application list awaiting correction. The copied catalogue paragraph is preserved in the private source review, not converted into a product capability claim.

Evidence for the selected model.

Factory and equipment photographs are available in the supplied materials. A model-matched project record and complete certificate scope have not yet been verified.

Awaiting confirmation: certificate annex and applicable models, complete ISO evidence, project dates, photograph attribution and measured results. No certification badge or performance result is asserted here.

View the limited customer display examples →

Discuss the support you need.

Gaode Equipment provides engineering services alongside equipment sales. The scope and responsibilities need to be agreed for your project.

Discuss engineering requirements
Scope awaiting confirmation

Process design, system integration, installation, commissioning, service locations, delivery times and warranty terms are not included as assumed commitments.

Tell us about your material.

Share the material, process conditions, intended separation and project location. Tell us which specifications you need to resolve.

jayden@gaodetec.com

Online delivery is not enabled in this preview. The form checks your entries; it does not send an inquiry.

Preview only: this form does not send inquiries. You can contact our team by email.

Contact details awaiting confirmation

This channel is not enabled in the preview. Please use our confirmed email address:

jayden@gaodetec.com